DEUTSCH I ENGLISH
Home I Service I faq I News I Contact
Data AcquisationTemperatureHumidityWindPressureRadiationPrecipitation, EvaporationTest, CalibrationAccessories
1. Sensors for global radiation

ProduktName

3. Radiation balance sensors

ProduktName

5. Sensors for sunshine duration


  

Group 6: Radiation

40xxx

 

 

 

ProduktName

 





Zoom

Type-No.: 6020.0000
Radiation Balance Meter
WMO, class 1, to measure the difference between incident radiation and reflected radiation at a short and long spectral  range. The black lacquered copper plates at both sides are connected to thermopiles measuring the temperature of the  differentially heated plates and thus forming the difference. Protection by "Lupolen" domes which are pervious for radiation  in the mentioned spectral range. Supplied with fastening bracket, desiccant vessel and box levels.    

Spectral range:
0.3...60 μm 
Sensitivity:
approx. 9 μV/Wm -2, indiv. cal.    
Measuring range:
approx. 1050 Wm -2 max., indiv. cal.   
Impedance:
approx. 5 Ω
Response time:
approx. 20 s for 95 % FS 
Operating temp.:
-40...+60°C 
Connection cable:
approx. 3 m 
Fastening:
stainl. steel rod ∅ 8 mm, L=400 mm 
Dimensions/Weight:
520 x 50 x 30 mm / approx. 0.35 kg  





Zoom

Type-No.: 6024.0000
Net radiometer
with integrated Pt 100 temperature sensor and 12 V heating 

The net radiometer is suitable  particularly for analysing the short and  long wave net radiation. 
The device consists: 
- Four separate detectors with equal  sensitivity. 
- A rugged and weatherproof housing 
- Built-in heating element 
- Built-in Pt 100 temperature probe

Application: 
- Agrometeorology: Investigation of  Evapotranspiration 
- Climatology: Investigation of net  radiation 
- Building structure research:  Measurement of  thermal load 
- Solar energy: Investigation of heat  exchange at termal solar systems  
- Permanent road monitoring 
- Prevention of crop damage   

Special features: 
- All 4 sensors have equal sensitivity 
- Pt 100 in acc. to DIN, class A  
- Heating resistor 24 Ω, 6 W at 12 V     

Suitable data acquisition devices :
- For net radiation, only:     one mV- channel 
- For all four components:  four mV - channels,   
                                                one Pt 100 channel  incl. software

  short wave:                            long wave: 
Response time:
18 s                                        18 s
Adjust. error:
< 25 W/m 2                             n. a.
Spectral range:
305...2800 nm                        5000...50.000 nm   
Expected output 
under atmospheric
conditions:               
0...50 mV                               -25...+25 mV 
Operating temp.: -40...+70°
Expected accuracy 
of the daily total 
values:
± 10 % 
Length of cable:
10 m
Weight:
4 kg


techn. Daten