Group 3: Humidity
|
|
40xxx
|
|
|
|
|
ProduktName
|

Zoom | Type-No.: 3503.0000 Tensiometer to measure soil moisture, calculated from the difference between ambient air pressure and reduced pressure in the soil, caused by water tension. Measured by means of a pressure sensor, semi-permeable ceramic sucti on head and water-filled head as transducer. External refilling. Built-in temperature sensor to measures oil temperature.
Suction head:
|
Special ceramic SKA 100-FF Dimensions: 60 x 24 mm
|
Head:
|
Length = 80 mm
|
Shaft:
|
Ø 25 mm, length = 300 mm (standard) other length up to 2 m upon request
|
Measuring range:
|
-1000...+850 hPa soil water tension -30...+70°C soil temperature
|
Signal:
|
0...2 V soil water tension 0...2 V soil temperature
|
Supply:
|
6...20 V DC, approx. 7 mA |
Accuracy:
|
Soil water tension ± 5 hPa Temperature ± 0.2 K (-10...+10°C) respect. ± 0.5 K (-30...+70°C)
|
Shaft material:
|
Acrylic glass, ∅ 25 mm, suitable for winter operation at frost protected immersion depth
|
Intake f. reference pressure:
|
via porous cable membran
|
Cable length:
|
5 m (standard); other lengths up to 20 m upon request 8 pole connector IP 67
|
|

Zoom | Type-No.: 3505.2000 Equitensiometer This instrument is based on a patented method to detect the matric potential in the soil (Matric potential is an expression for the amount of energy which is necessary to extract a certain amount, for example 1 gram, of water out of the soil; its unit is kPa). During equilibrium, the matric potential between neighbouring sections of soil is equal , independent from particle size configuration, humus content, density etc.. The equitensiometer takes advantage of this characteristic by getting a ceramic equilibrium probe with known soil moisture characteristic curve in contact with the soil to be measured. After detection of the probe’ s water content by means of the FDR-principle, the matric potential is directly determined.
Dimensions:
|
40 x 20 mm, length 170 mm
|
Weight:
|
approx. 0.6 kg incl. 5 m cable
|
Cable length:
|
Standard: 5 m; max. 100 m
|
Operating conditions:
|
Soil with low salinity < 1 mS/cm, pH 2...8.5, temperature 0...40°C (below 0°C: wrong measuring values, but no damage to the probe)
|
Output:
|
0...700 mV |
Supply:
|
5...15 V DC, max. 23 mA meas. interval 10 s
|
| Application range: |
Precision soil monitoring for hydrology and plant physiology, control of irrigation systems, detection of water stress
|
Meas. Range:
|
0...-1500 kPa
|
Accuracy:
|
± 5 kPa at 0...-100 kPa < 5% at –100...-1500 kPa
|
|
|
techn. Daten
|
| |
|